HBS57 Stepper Motor Driver Controller

Feature:

Product Characteristics

HBS57 Adopt unique algorithm, low heating, high torque voltage range: AC18~ AC80V/DC20~ DC110V 16-file subdivision, can be customized according to customer requirements, 5~24V input compatible, no need for external series resistance, maximum response frequency 400KHZ
The torque attenuation is small, and the maximum speed can reach 3000rmp
External alarm and in-place output port, convenient to monitor and control intelligent current regulation, reduce power consumption at low load, increase torque at high load. Effective current can be set by dial-code switch, single and double pulses can be set by adapting different motor dial-code switch, factory default pulse + direction control
The dial switch sets pulse delay, and the factory defaults to 40ms. Excellent high-speed performance and rigidity perfectly integrate the advantages of servo and stepping

Typical application

Mainly used in engraving machines, special industrial sewing machines, stripping machines, marking machines, cutting machines, laser phototypesetting, plotters, numerical control machine tools, dispensing machines, screw machines and other automation equipment and instruments

Product Overview

HBS57 Stepper Motor Driver adopts the latest digital integrated motor control chip and vector closed-loop control technology, so as to completely overcome the problem of step loss of open-loop stepping motor, and at the same time, it can obviously improve the high-speed performance of the motor, reduce the heating degree and vibration of the motor, thus improving the processing speed and accuracy of the machine and reducing the energy consumption of the machine. In addition, when the motor is continuously overioaded, the driver will output alarm signals, which has the same reliability as AC servo control system, and the cost is far lower than that of traditional AC serve system. It is a motion control product with high cost performance

Model:

其他信息

Model

HBS57

Thanks for sharing it !

Proudct Information:

Description

Nema 23  HBS57 Stepper Motor Driver Low Noise Smooth Running 16-70V 7A Closed Loop

MARKED SYMBOL
FUNCTION
CONDITIONAL COMMENT
PWR/FLT
Voltage and fault indicator
Green flashing: the driver is normal, no pulse signal is received: green steady on: pulse signal is received, the motor rotates;One red and one green: overcurrent or interphase short-circuit fault; Two red and one green: No motor or motor wiring error detected; Three red and one green: overvoltage fault; Four red and green: undervoltage fault, five red and green: tracking error overerror fault
PUL+
Pulse input signal photoelectric isolation positive end
Pulse signal voltage 5~24V can be driven
PUL-
Pulse input signal photoelectric isolation negative end
The falling edge is effective, and the motor takes a step whenever the pulse changes from high to low. Pulse width greater than 2.5 microseconds
DIR+
Direction input signal photoelectric isolation positive end
Direction signal voltage 5~24V can be driven
DIR-
Direction input signal photoelectric isolation negative end
Used to change motor steering. The falling edge is effective, and the motor takes a step whenever the pulse changes from high to
low. Pulse width greater than 2.5 microseconds
EN+
The positive end of the input signal was enabled
Enable signal voltages from 3.3 to 24V can be driven
EN-
The negative end of the input signal was enabled
When effective (low level) turn off the motor coil current, the motor is in the free state and clear the alarm signal
EX+
Position signal output positive end
When the driver completes the given pulse, the position signal is effective (output optocoupler conduction). EX+ connects the pull
resistor to the positive terminal of the output power supply, and EX- connects to the negative terminal of the output power
supply. The maximum driving current is 10mA.
EX-
Position signal output negative end
ALM+
Alarm signal output positive end
When the red light blinks, the alarm signal is effective (output optocoupler conduction). ALM+ connects the pull resistor to the
positive terminal of the output power supply, and ALM- connects to the negative terminal of the output power supply. The maximum
driving current is 10mA.
ALM-
Alarm signal output negative end
VCC
Encoder power positive
Encoder 5V power supply positive end
EGND
encoelectrically
encoelectrically
EB+
Encoder B phase input positive end
Encoder B channel positive input
EB-
Encoder B phase input negative end
Encoder B channel negative input
EA+
Encoder phase A input positive end
Encoder A channel positive input
EA-
Encoder A phase input negative end
Encoder A channel negative input
A+
Motor wiring A+
A-
Motor wiring A-
B+
Motor wiring B+
B-
Motor wiring B-
AC1
Driver power supply
Voltage range: AC18~AC80V/DC20~DC110V
AC2
Driver power supply

Operating environment and parameters

Cooling method Natural cooling or forced air cooling
Use environment Occasion Avoid dust, oil, corrosive gas, high humidity and strong vibration. Combustible gas and conductive dust are prohibited.
temperature 0℃—50℃
Humidity 40-90%RH
Vibration 10-55Hz/0.15mm
Storage temperature -20℃—65℃
Weight 0.25kg

 

Faradyi Motors Service

How to use the motor

1. Use tolerance: pay attention to the use range of voltage and current, and use the motor under the conditions specified in this standard, otherwise the life of the motor will be reduced.
2. Handling the motor: handle it with care, and use the motor casing as much as possible.
3. Motor wiring: the red lead wire is connected to the positive pole, and the black lead wire is connected to the negative pole. If the connection is reversed, the motor will rotate in the opposite direction.
4. Overload: Use it within the specified load range as much as possible. It is strictly forbidden to run the motor in a stalled state or close to the stalled state for a long time, otherwise the motor will burn out.
5. Motor storage:Storage temperature: 0C-40°C, storage humidity: 15%-90% RH
Avoid placing it in an environment with high temperature, high humidity and corrosive gas.
6. Motor operating temperature: 0°C-70C

Motor Precautions

1. When you use the motor, there must be no binding objects, such as adhesive, do not flow into the bearing through the rotating shaft, which will hinder the operation of the motor.
2. The rotation of the shaft may have the opposite effect on the life of the motor. In order to prolong the life, please check whether your load is in accordance with the regulations. Do not overload or hang items that hinder the rotation of the shaft.
3. Manufactured into an eccentric heavy radiation load, harmful to the life of the motor.
4. Do not store it in high temperature or extreme humidity, and do not place it in corrosive gas, which will reduce the effect of the motor
5. Do not run the motor in the surrounding high temperature and humidity.
6. When soldering on the positive and negative motor terminals of the power supply, the temperature of the soldering iron is 340C40C, and the heating time is within 3 seconds. Do not deform the plastic. Let the solder point flow into the motor or break the end of the wire during work, which will make the motor function decline.
7. Do not let the motor shaft get stuck. When the power is supplied, the motor will overheat in a short time and burn its accessories.
8. Supply the specified power and make sure it is within the range of measurable requirements.
9. When installing pulleys or gears, do not increase the weight abnormally when pressing them in.
10. When installing the motor, if the screw is too long, it will cause contact between the motor itself and the
rotor, which will affect the characteristics.

Related Products

Submit a Quick Quote

Don't Take Our Word for It - See What Customers Say

We strive to provide exceptional products and service. If you are satisfied with your experience, we would greatly appreciate you taking a moment to leave us a review

en_USEnglish

Product Inquiry

Product Inquiry