- (+086) 18923470557
- [email protected]
- 7F, No.53 Fofu Road, Dalang Town, Dongguan City, Guangdong, CN,523770
Thanks for sharing it !
Proudct Information:
Description
MARKED SYMBOL
|
FUNCTION
|
CONDITIONAL COMMENT
|
PWR/FLT
|
Voltage and fault indicator
|
Green flashing: the driver is normal, no pulse signal is received: green steady on: pulse signal is received, the motor rotates;One red and one green: overcurrent or interphase short-circuit fault; Two red and one green: No motor or motor wiring error detected; Three red and one green: overvoltage fault; Four red and green: undervoltage fault, five red and green: tracking error overerror fault
|
PUL+
|
Pulse input signal photoelectric isolation positive end
|
Pulse signal voltage 5~24V can be driven
|
PUL-
|
Pulse input signal photoelectric isolation negative end
|
The falling edge is effective, and the motor takes a step whenever the pulse changes from high to low. Pulse width greater than 2.5 microseconds
|
DIR+
|
Direction input signal photoelectric isolation positive end
|
Direction signal voltage 5~24V can be driven
|
DIR-
|
Direction input signal photoelectric isolation negative end
|
Used to change motor steering. The falling edge is effective, and the motor takes a step whenever the pulse changes from high to
low. Pulse width greater than 2.5 microseconds |
EN+
|
The positive end of the input signal was enabled
|
Enable signal voltages from 3.3 to 24V can be driven
|
EN-
|
The negative end of the input signal was enabled
|
When effective (low level) turn off the motor coil current, the motor is in the free state and clear the alarm signal
|
EX+
|
Position signal output positive end
|
When the driver completes the given pulse, the position signal is effective (output optocoupler conduction). EX+ connects the pull
resistor to the positive terminal of the output power supply, and EX- connects to the negative terminal of the output power supply. The maximum driving current is 10mA. |
EX-
|
Position signal output negative end
|
|
ALM+
|
Alarm signal output positive end
|
When the red light blinks, the alarm signal is effective (output optocoupler conduction). ALM+ connects the pull resistor to the
positive terminal of the output power supply, and ALM- connects to the negative terminal of the output power supply. The maximum driving current is 10mA. |
ALM-
|
Alarm signal output negative end
|
|
VCC
|
Encoder power positive
|
Encoder 5V power supply positive end
|
EGND
|
encoelectrically
|
encoelectrically
|
EB+
|
Encoder B phase input positive end
|
Encoder B channel positive input
|
EB-
|
Encoder B phase input negative end
|
Encoder B channel negative input
|
EA+
|
Encoder phase A input positive end
|
Encoder A channel positive input
|
EA-
|
Encoder A phase input negative end
|
Encoder A channel negative input
|
A+
|
Motor wiring A+
|
|
A-
|
Motor wiring A-
|
|
B+
|
Motor wiring B+
|
|
B-
|
Motor wiring B-
|
|
AC1
|
Driver power supply
|
Voltage range: AC18~AC80V/DC20~DC110V
|
AC2
|
Driver power supply
|
Cooling method | Natural cooling or forced air cooling | |
Use environment | Occasion | Avoid dust, oil, corrosive gas, high humidity and strong vibration. Combustible gas and conductive dust are prohibited. |
temperature | 0℃—50℃ | |
Humidity | 40-90%RH | |
Vibration | 10-55Hz/0.15mm | |
Storage temperature | -20℃—65℃ | |
Weight | 0.25kg |
Faradyi Motors Service
1. Use tolerance: pay attention to the use range of voltage and current, and use the motor under the conditions specified in this standard, otherwise the life of the motor will be reduced.
2. Handling the motor: handle it with care, and use the motor casing as much as possible.
3. Motor wiring: the red lead wire is connected to the positive pole, and the black lead wire is connected to the negative pole. If the connection is reversed, the motor will rotate in the opposite direction.
4. Overload: Use it within the specified load range as much as possible. It is strictly forbidden to run the motor in a stalled state or close to the stalled state for a long time, otherwise the motor will burn out.
5. Motor storage:Storage temperature: 0C-40°C, storage humidity: 15%-90% RH
Avoid placing it in an environment with high temperature, high humidity and corrosive gas.
6. Motor operating temperature: 0°C-70C
1. When you use the motor, there must be no binding objects, such as adhesive, do not flow into the bearing through the rotating shaft, which will hinder the operation of the motor.
2. The rotation of the shaft may have the opposite effect on the life of the motor. In order to prolong the life, please check whether your load is in accordance with the regulations. Do not overload or hang items that hinder the rotation of the shaft.
3. Manufactured into an eccentric heavy radiation load, harmful to the life of the motor.
4. Do not store it in high temperature or extreme humidity, and do not place it in corrosive gas, which will reduce the effect of the motor
5. Do not run the motor in the surrounding high temperature and humidity.
6. When soldering on the positive and negative motor terminals of the power supply, the temperature of the soldering iron is 340C40C, and the heating time is within 3 seconds. Do not deform the plastic. Let the solder point flow into the motor or break the end of the wire during work, which will make the motor function decline.
7. Do not let the motor shaft get stuck. When the power is supplied, the motor will overheat in a short time and burn its accessories.
8. Supply the specified power and make sure it is within the range of measurable requirements.
9. When installing pulleys or gears, do not increase the weight abnormally when pressing them in.
10. When installing the motor, if the screw is too long, it will cause contact between the motor itself and the
rotor, which will affect the characteristics.
We strive to provide exceptional products and service. If you are satisfied with your experience, we would greatly appreciate you taking a moment to leave us a review
Faradyi manufactures high-quality brushless motors for aviation, robotics, medical, auto, machinery, new energy, and infrastructure industries globally.
Faradyi Motor Has Been Deeply Involved In The Motor Industry For Decades, Specializing In The Production Of Various Robots And Brushless Motors.Update more new news in real time~