Faradyi 24V Linear Electric Actuators

Feature:

Faradyi Linear Electric Actuators — Specifications

Attribute Specification
No-load Speed (mm/s) 15 / 30 / 45 / 60
Rated Thrust (N) 600 / 300 / 200 / 100
Pulling Force (N) 400 / 300 / 200 / 100
Self-locking (Thrust, N) 600 / 300 / 200 / 100
Self-locking (Tension, N) 400 / 300 / 200 / 100
Stroke Range 30–1000 mm (customizable)
Protection Level IP43
Duty Cycle S2 — 10 minutes (intermittent)
Inner Tube Material Aluminum alloy
Screw Type T-type screw
Limit Switch Built-in (optional magnetic induction switch)
Optional Features Magnetic sensor; end-position feedback
Working Temperature 0°C to +40°C
Noise Level ≤ 40 dB
Bottom Mounting Options CP lifting ear type; CG flat style
Top End Fittings Multiple options (default non-removable)
Typical Use Cases Medical equipment, office ergonomics, home automation, light industrial mechanisms

Speed / Force Profiles

Speed (mm/s) Rated Thrust (N)
15 600
30 300
45 200
60 100

Note: Speed and thrust are factory-set and cannot be adjusted after delivery. During extension and retraction, the load must not exceed the selected thrust (e.g., 600N ≈ 60 kg).

Model:

其他信息

Voltage(V)

24V DC

Model

IP600CG / IP600CP

Thanks for sharing it !

Category

Description

Faradyi linear electric actuators provide clean, precise push‑and‑pull motion for lifting, tilting, and positioning tasks. Engineered with a robust aluminum alloy housing and T‑type screw drive, they deliver up to 600N of thrust with strong self‑locking to keep loads safely in place when powered off. The built‑in limit switch ensures accurate end‑stroke protection, while optional magnetic sensor and end‑position feedback support integration with PLCs or smart controllers.

Key Features

  • High performance: Up to 600N thrust, 400N pulling force, and a wide 30–1000mm stroke range to fit diverse installations.
  • Precise end control: Built‑in limit switch automatically cuts power at end‑stroke; optional magnetic induction switch and feedback enable monitoring and closed‑loop control.
  • Quiet operation: ≤40 dB — ideal for medical spaces, offices, and home environments.
  • Durable construction: Thickened aluminum inner tube plus plastic gear train for lower noise, reduced oxidation, and long service life.
  • Safe & clean: IP43 protection against dust and water splashes; S2‑10 min duty cycle for intermittent operation.
  • Flexible mounting: Bottom options include CP lifting ear and CG flat style; multiple top end fittings (default non‑removable).

linear electric actuators Performance Options

  • Speed/Force profiles:
    • 15 mm/s → 600 N
    • 30 mm/s → 300 N
    • 45 mm/s → 200 N
    • 60 mm/s → 100 N Note: Speed and thrust are factory‑set and cannot be adjusted after delivery. During extension and retraction, the load must not exceed the selected thrust (e.g., 600N ≈ 60 kg).

linear electric actuators Applications

  • Medical: Hospital beds, patient lifts, treatment tables requiring quiet, safe positioning.
  • Office: Height‑adjustable desks, monitor lifts, partitions.
  • Home: Recliners, TV lifts, smart furniture, window openers.
  • Light industrial: Louvers, machine guards, fixtures needing intermittent linear motion.

linear electric actuators Installation & Integration

  • Power: 24V DC; reverse polarity changes direction.
  • Control: Simple switch/relay or MCU‑based drivers; integrate limit signals for safe stops.
  • Mounting: Select CP or CG bottom style; verify installation distance per drawing and keep alignment to avoid side loads.
  • Sensing: Optional magnetic induction switch and end‑position feedback for system integration.

linear electric actuators Reliability & Safety

  • Strong self‑locking prevents back‑drive when powered off.
  • IP43 protection suits indoor and sheltered environments.
  • Aluminum alloy structure resists corrosion; plastic gears reduce noise and breakage risk.

Why Choose Faradyi Linear Electric Actuators

  • Balanced force, speed, and low noise performance
  • Wide stroke range and modular mounting options
  • Built‑in protections with optional feedback for easy integration
  • Reliable quality and competitive total cost of ownership

Faradyi Motors Service

How to use the motor

1. Use tolerance: pay attention to the use range of voltage and current, and use the motor under the conditions specified in this standard, otherwise the life of the motor will be reduced.
2. Handling the motor: handle it with care, and use the motor casing as much as possible.
3. Motor wiring: the red lead wire is connected to the positive pole, and the black lead wire is connected to the negative pole. If the connection is reversed, the motor will rotate in the opposite direction.
4. Overload: Use it within the specified load range as much as possible. It is strictly forbidden to run the motor in a stalled state or close to the stalled state for a long time, otherwise the motor will burn out.
5. Motor storage:Storage temperature: 0C-40°C, storage humidity: 15%-90% RH
Avoid placing it in an environment with high temperature, high humidity and corrosive gas.
6. Motor operating temperature: 0°C-70C

Motor Precautions

1. When you use the motor, there must be no binding objects, such as adhesive, do not flow into the bearing through the rotating shaft, which will hinder the operation of the motor.
2. The rotation of the shaft may have the opposite effect on the life of the motor. In order to prolong the life, please check whether your load is in accordance with the regulations. Do not overload or hang items that hinder the rotation of the shaft.
3. Manufactured into an eccentric heavy radiation load, harmful to the life of the motor.
4. Do not store it in high temperature or extreme humidity, and do not place it in corrosive gas, which will reduce the effect of the motor
5. Do not run the motor in the surrounding high temperature and humidity.
6. When soldering on the positive and negative motor terminals of the power supply, the temperature of the soldering iron is 340C40C, and the heating time is within 3 seconds. Do not deform the plastic. Let the solder point flow into the motor or break the end of the wire during work, which will make the motor function decline.
7. Do not let the motor shaft get stuck. When the power is supplied, the motor will overheat in a short time and burn its accessories.
8. Supply the specified power and make sure it is within the range of measurable requirements.
9. When installing pulleys or gears, do not increase the weight abnormally when pressing them in.
10. When installing the motor, if the screw is too long, it will cause contact between the motor itself and the
rotor, which will affect the characteristics.